Description
The MAGUS Metal V700 metallurgical inverted microscope is designed for studying the microstructure of metals, alloys and semiconductor materials in reflected light. The specimen stage can hold samples up to 2 kg (only the bottom surface of the sample needs to be flat). Other parts of the sample do not require processing and can be of any shape. The microscope is designed for observations using the brightfield method and polarized light, has a side camera port and a trinocular tube, and is suitable for a large number of laboratory and industrial applications.
Using the microscope »
Digital camera
The MAGUS CBF30 digital camera gives you the ability to take photos and videos through the microscope, edit the resulting files, organise presentations and carry out linear and angular measurements of objects (after proper calibration).
The device is designed for use with microscopes that use the brightfield method and objectives with magnification of 4x, 10x, 20x and 40x.
The 6.3 MP sensor gives you the ability to take bright, detailed photos and videos with a maximum resolution of 3072x2048 px. If necessary, the resolution can be reduced to 1536x1024 px. This, however, will not affect the frame rate, which will remain 59 fps, thus ensuring smooth frame transitions without flickering or lag.
The colour CMOS Exmor sensor with back illumination gives you the ability to use the camera even in low light. The image will remain distinct and bright. Using an adapter with magnification from 0.5x to 0.75x will ensure the clearest possible image without distortion.
Optics
The microscope is equipped with a trinocular head of special construction – the position of the eyepieces can be adjusted; there is the option of rotating it by 180°. The digital camera is mounted in the side camera port on the microscope body, and the monitor is mounted in the trinocular tube of the microscope head. The beam splitting in the body is 100:0/0:100, and in the trinocular head – 50:50 and 100:0.
The revolving nosepiece is located below the examined sample and has 5 objective slots (all of them are included in the basic configuration). All objectives are plan achromatic with infinity correction, with long working distances. An additional objective may be mounted in place of any of the supplied objectives. In the basic configuration the magnification of the microscope is from 50x to 1000x.
Illumination
The reflected light illuminator has a halogen bulb with a power of 30 W with adjustable brightness. AC power is supplied to the lamp housing. It has sufficient brightness for observations with all supplied objectives, using the brightfield and polarization microscopy methods. There is an option for Köhler illumination adjustment, and the light source can be adjusted along three axes. Colour filters can be used to change colour rendering in microscope photography. There are polarization devices – an analyser and a polariser, both of which can be removed.
Specimen stage and focusing mechanism
A round rotating carrier plate with holes 10 mm, 20 mm or 30 mm, which is inserted into the specimen stage, and the sample is fixed using a sample holder. The specimen stage is quite large (242x200 mm) and moves with the sample fixed on it along two axes. You can adjust image sharpness using the coarse and fine focusing knobs. You can adjust the tension of the coarse focusing knob, and there is also a locking knob.
Accessories
Additional accessories allow you to make the most of the MAGUS Metal V700 microscope. There are eyepieces, plan achromatic objectives with a long working distance, calibration samples and digital cameras.
Main features of the microscope:
- Examination of large and heavy samples using the brightfield and polarization microscopy methods; only one side of the sample can be observed
- Large specimen stage, round rotating plates on the stage, with holes 10 mm, 20 mm and 30 mm
- During assembly the trinocular head can be rotated by 180°
- Two options for mounting a digital camera and monitor: on the trinocular head with beam splitting 50:50 and 100:0, or on the microscope body with beam splitting 100:0 or 0:100
- Observations in reflected light, light source – halogen bulb 30 W with adjustable brightness
- Köhler illumination adjustment, analyser and polariser that can be removed, and a light source that can be centred
- A large set of additional accessories to extend the capabilities of the microscope
Main features of the camera:
- Use of low-magnification objectives is recommended
- Colour light-sensitive sensor for obtaining clear images, even in low light
- Frame rate of 59 fps, which is sufficient for observing moving objects and rapidly occurring processes
- The kit includes software that fully ensures the operation of all camera functions and, accordingly, a "quick start"
- Reliable USB 3.0 interface for high data transfer speeds
- Resolution adjustment, so you can choose the most suitable option at any time
The kit includes:
- MAGUS CBF30 digital camera (digital camera, USB cable, installation CD with drivers and software, user manual and warranty card)
- Base with power input, focusing mechanism, specimen stage and revolving nosepiece
- Reflected light illuminator with illuminator body housing
- Trinocular head
- Plan achromatic objective with infinity correction: PL L5x/0.12 WD 26.1 mm
- Plan achromatic objective with infinity correction: PL L10x/0.25 WD 20.2 mm
- Plan achromatic objective with infinity correction: PL L20x/0.40 WD 8.80 mm
- Plan achromatic objective with infinity correction: PL L50x/0.70 WD 3.68 mm
- Plan achromatic objective with infinity correction: PL L100x/0.85 (dry) WD 0.40 mm
- Eyepiece 10x/22 mm with wide eye relief (2 pcs.)
- C-mount adapter 1x
- Hex key
- AC power cable
- Dust cover
- User manual and warranty card
Available on request:
- Eyepiece 10x/22 mm with scale
- Eyepiece 12.5x/14 mm (2 pcs.)
- Eyepiece 15x/15 mm (2 pcs.)
- Eyepiece 20x/12 mm (2 pcs.)
- Eyepiece 25x/9 mm (2 pcs.)
- Plan achromatic objective with infinity correction: PL L40x/0.60 WD 3.98 mm
- Plan achromatic objective with infinity correction: PL L60x/0.70 WD 2.08 mm
- Plan achromatic objective with infinity correction: PL L80x/0.80 WD 1.25 mm
- Calibration sample
Specifications
| Warranty | 5 years |
|---|---|
| Package dimensions (L x W x H) | 49x34x68 cm |
| Shipping weight | 17.1 kg |
| Type | metallurgical, light/optical, digital |
| Microscope head type | trinocular |
| Head | Siedentopf, can be rotated 180° |
| Head inclination angle | 45° |
| Magnification, x | 50 — 1000 |
| Magnification range | from 800x to 1280x |
| Magnification, x (option) | 50–1250/1500/2000/2500 |
| Eyepiece tube diameter, mm | 30 |
| Eyepieces | 10x/22 mm, eye relief: 10 mm (*option: 10x/22 mm with scale, 12.5x/14; 15x/15; 20x/12; 25x/9) |
| Objectives | planachromatic with infinity correction: PL L5x/0.12, PL L10x/0.25, PL L20x/0.40, PL L50x/0.70, PL L100x/0.85 (dry); parfocal distance 45 mm (*option: PL L40x/0.60, PL L60x/0.70, PL L80x/0.80) |
| Nosepiece | for 5 objectives |
| Working distance, mm | 26.1 (5x); 20.2 (10x); 3.98 (40x); 2.08 (60x); 8.80 (20x); 3.68 (50x); 1.25 (80x); 0.40 (100x) |
| Interpupillary distance, mm | 48 — 75 |
| Stage size, mm | 242x200 |
| Stage travel range, mm | 30/30 |
| Stage characteristics | two-axis mechanical, round rotating central plate with Ø130 mm and holes Ø10 mm, Ø20 mm and Ø30 mm |
| Diaphragm | built-in aperture and field |
| Focusing | coaxial, coarse (with coarse focus tension adjustment and locking button) and fine (0.002 mm) |
| Body | solid aluminium |
| Illumination | halogen |
| Brightness adjustment | yes |
| Power supply | 220±22 V, 50 Hz, alternating current mains |
| Light source type | 12 V/30 W |
| Light filters | green, blue, yellow, frosted |
| Operating temperature range, °C | 5 — 35 |
| Additional | removable analyser and polariser |
| User level | for professionals, experienced users |
| Assembly and installation difficulty level | complex |
| Application | metallurgical |
| Illumination location | bottom (reflected light) |
| Examination method | brightfield, polarization |
| Included bag/case/pouch | dust cover |
| Sensor | SONY Exmor CMOS |
| Colour/monochrome | colour |
| Megapixels | 6.3 |
| Maximum resolution, pixels | 3072x2048 |
| Sensor size | 1/1.8" (7,37x4,92 mm) |
| Pixel size, μm | 2.4x2.4 |
| Light sensitivity | 425 mV at 1/30 s |
| Signal-to-noise ratio | 0.15 mV at 1/30 s |
| Exposure time | 0.02 ms – 15 s |
| Video recording | Yes |
| Frame rate, fps at resolution | 59 at 1536x1024, 59 at 3072x2048 |
| Mounting location | trinocular tube, eyepiece tube instead of eyepiece |
| Image format | *.jpg, *.bmp, *.png, *.tif |
| Video format | output: *.wmv, *.avi, *.h264 (Windows 8 and later), *h265 (Windows 10 and later) |
| Spectral range, nm | 380–650 (built-in infrared filter) |
| Shutter type | ERS (electronic rolling shutter) |
| White balance | automatic, manual |
| Exposure control | automatic, manual |
| Software features | exposure time, image size, brightness |
| Software | MAGUS View |
| Output | 5 Gb/s, USB 3.0 |
| System requirements | Windows 8/10/11 (32-bit and 64-bit), Mac OS X, Linux, up to 2.8 GHz Intel Core 2 or more powerful, at least 2 GB RAM, USB 3.0 port, CD-ROM, 17" or larger display |
| Mount type | C-mount |
| Camera power supply | DC, 5 V, from the USB port of a computer; adapter for 12 V, 3 A to power the Peltier element |
| Camera operating temperature range, °C | -10 — 50 |
| Operating humidity range, % | 30 — 80 |